Power-sonic PSH-12180FR User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
CORPORATE OFFICE7550PanasonicWay•SanDiego,CA92154•USA•Tel:+1-619-661-2020•Fax:+1-619-661-3650
CUSTOMER SERVICE
Tel:+1-619-661-2030
Fax:+1-619-661-3648
customer-service@power-sonic.com
INTERNATIONAL SALES
Tel: +1-650-364-5001
Fax: +1-650-366-3662
international-sales@power-sonic.com
DOMESTIC SALES
Tel:+1-619-661-2020
Fax:+1-619-661-3650
national-sales@power-sonic.com
TECHNICAL SUPPORT
Tel:+1-619-661-2020
Fax:+1-619-661-3648
support@power-sonic.com
Contact Information
www.power-sonic.com
0812 1M
© 2012. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners.
Charging
Cycle Applications:Limitinitialcurrentto6.3A.Chargeuntilbatteryvoltage
(undercharge)reaches14.4to14.7voltsat68°F(20°C).Holdat14.4to14.7
volts until current drops to under 210mA. Battery is fully charged under these
conditions,andchargershouldbedisconnectedorswitchedto“oat”voltage.
“Float” or “Stand-By” Service:Holdbatteryacrossconstantvoltagesourceof
13.5to13.8voltscontinuously.Whenheldatthisvoltage,thebatterywillseekits
own current level and maintain itself in a fully charged condition.
Note: Due to the self-discharge characteristics of this type of battery, it is
imperative that they be charged within 6 months of storage, otherwise permanent
loss of capacity might occur as a result of sulfation.
Chargers
Power-Sonicoffersawiderangeofchargerssuitableforbatteriesupto100AH.
PleaserefertotheChargerSelectionGuideinourspecicationsheetsfor“C-Series
SwitchModeChargers”and“TransformerTypeAandFSeries”.Pleasecontactour
Technicaldepartmentforadviceifyouhavedifcultyinlocatingsuitablemodels.
Capacity Retention Ratio (%)
Standing Period (Months)
100
80
60
40
0
0 2 4 6 8 10 12 14 16 18 20
40
o
C
(104
o
F)
30
o
C
(86
o
F)
20
o
C
(68
o
F)
5
o
C
(41
o
F)
Charging is not
necessary unless
100% of capacity
is required.
Charging before
use is necessary
to help recover
full capacity.
Chargemay fail
to restore full
capacity. Do not
let batteries reach
this state.
Discharge Characteristics
Discharge Time vs. Discharge Current
Shelf Life & Storage
PSH-12180FR 12 Volt 21.0 AH
®
Further Information
Pleaserefertoourwebsitewww.power-sonic.comforacompleterangeofuseful
downloads,suchasproductcatalogs,materialsafetydatasheets(MSDS),ISO
certication,etc..
Constant Power Discharge Ratings
MODEL
FINAL
VOLTAGE
WATTS PER CELL @ 25° C
5 MIN 10 MIN 15 MIN 20 MIN 30 MIN 45 MIN 60 MIN
PSH-12180FR
1.75 140 106 80 65 50 36 26
1.70 142 107 80 66 51 37 26
1.67 144 108 82 67 52 38 27
10
9
8
7
6
5
4
3
2
60
50
40
30
20
10
8
6
4
0 .65 1.27 2.08 2.3 2.8 4 7 13 21 41 62 75
Discharge Current (A)
Discharge Time
40°C (104°F)
25°C (77°F)
0°C (32°F)
min. hrs.
Discharge Time
Terminal Voltage (V)
13.0
min. hrs.
12.0
11.0
10.5
10.0
9.6
9.0
8.0
7.8
2010532125 20 30 6031.50
1.05A2.0A3.7A
5.7A
13A
20A
40A60A
Page view 1
1 2