Physical Dimensions: in (mm)
Features
Superb high-rate discharge characteristics that ensure reliable
performance in UPS applications for up to 10 years. UL recognized
Flame retardant ABS case and cover to UL 94 V-O for superior
performance
VRLA Absorbent Glass Mat (AGM) Technology guarantees safe
operation without maintenance and “non-restricted article” status for
transportation. Approved for transport by air. D.O.T., I.A.T.A. and
F.A.A. certified.
Precision plate pasting for higher consistency with 100% load
testing to ensure uniform capacity
Patented dual-paste process for enhanced active material bonding,
and computer guided volumetric electrolyte control for precision
filling
Lead-calcium alloy grids and the use of high purity lead account for
superior shelf-life characteristics
Performance Specifications
Nominal Voltage ............................................... 12 volts (6 cells)
Nominal Power (15 min.) .....................................430 W/Cell
Rated Capacity
20-hr. (5.50A to 10.80 volts) .................................... 110.0 AH
10-hr. (10.70A to 10.50 volts) .................................. 107.0 AH
8-hr. (12.90A to 10.50 volts) .................................. 103.2 AH
Approximate Weight .................................. 69.2 lbs. (31.4 kg)
Internal Resistance (approx.) ............................. 3.6 milliohms
Max Discharge Current (5 Sec.) ....................... 1650 amperes
Operating Temperature
Discharge ........................................... -15 ~ 50°C (5 ~ 122°F)
Charging ............................................. 0 ~ 40°C (32 ~ 104°F)
Storage .............................................. -15 ~ 40°C (5 ~ 104°F)
Maximum Charging Current ........................................ 33.0 A
Case ........................... Flame Retardant ABS Plastic (UL 94 V-O)
PHR-12400
L: 12.81(326) W: 6.69 (170) H: 8.39 (213) HT: 8.50 (216)
12 Volt 110 AH @ 20-hr. rate
430 W/Cell @ 15-min. rate
Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions.
www.power-sonic.com
To ensure safe and efcient operation always refer to the latest edition of our Technical Manual, as published on our website.
All data subject to change without notice.
Constant Current Discharge (Amperes) at 25ºC Constant Power Discharge (Watts/Cell) at 2C (Blue)
HT
H
W
L
020
M6
3
PHR-12400 5 min 10 min 15 min 20 min 30 min 45 min 1h 2h 3h 4h 5h 6h 8h 10h 20h
1.85V 216.5 183.3 159.3 136.4 104.9 76.9 61.6 35.8 26.4 21.2 17.8 15.4 12.3 10.3 5.38
1.80V 264.0 210.3 176.9 149.5 112.4 82.9 65.6 37.7 27.6 22.0 18.5 15.9 12.6 10.5 5.50
1.75V 297.0 230.3 193.6 161.7 119.7 86.8 68.9 39.5 28.7 22.6 18.8 16.3 12.9 10.7 5.63
1.70V 335.3 254.1 209.9 173.9 128.0 91.8 72.5 41.1 29.6 23.2 19.3 16.6 13.2 10.9 5.72
1.67V 363.0 275.2 227.0 186.8 135.3 96.5 75.9 42.4 30.4 23.8 19.8 17.0 13.5 11.1 5.82
1.60V 390.7 298.7 243.3 198.3 142.6 100.3 78.4 43.8 31.2 24.6 20.3 17.5 13.8 11.3 5.98
1.85V 421.2 358.6 313.4 269.7 208.5 153.4 123.4 71.9 53.3 42.9 36.1 31.4 25.2 21.2 11.1
1.80V 508.2 407.2 344.5 292.7 221.4 164.2 130.4 75.5 55.4 44.4 37.4 32.3 25.8 21.5 11.3
1.75V 565.9 441.9 373.7 313.9 233.7 170.6 136.0 78.5 57.2 45.3 37.8 32.8 26.2 21.8 11.5
1.70V 631.6 482.1 400.4 334.0 247.6 178.7 142.0 81.1 58.7 46.2 38.4 33.3 26.6 22.1 11.6
1.67V 678.3 518.2 430.4 356.5 260.1 186.8 148.0 83.2 60.0 47.2 39.2 33.8 26.9 22.3 11.8
1.60V 721.9 556.4 456.5 374.9 271.3 192.4 151.4 85.1 61.1 48.2 40.0 34.5 27.3 22.5 12.0